Sharing experiences in designing fire protection systems for factories in Dong Nai. Chuan A provides consultancy for fast PCCC design approval, material optimization, and 3D BIM applications
In the context of increasingly strict safety standards in Vietnam, especially the roadmap towards 2026, a fire protection design is more than just technical lines. It is a commitment to the safety of life and property and a legal "passport" for businesses to operate.
In key industrial parks of Dong Nai such as Amata, Long Binh, or Nhon Trach, a poor PCCC design can cause investors billions of VND in losses due to system repairs after construction because it doesn't match reality or fails approval. Chuan A Construction, with "combat" experience in hundreds of projects, shares its "blood and bone" experiences to help businesses achieve the most optimized fire protection design.
Fire protection design is not about copying. Each factory has its own characteristics (Garment, chemical, electronics...) corresponding to different fire hazard levels.
Designers must master TCVN 3890:2023, QCVN 06:2022/BXD, and supplementary circulars for 2026. Applying the wrong fire resistance rating for materials (such as fire-resistant paint or panels) right on the drawing will lead to the failure of the entire inspection dossier later.
The blueprint must clearly show the hazard group of each area. For example: A finished plastic warehouse requires a much higher intensity Sprinkler system than a mechanical processing area. Designing "just enough" according to standards will help investors save 15-20% on material costs.
Chuan A always prioritizes practicality and the long-term operational durability of the system.
This is the weapon that helps Chuan A reach the Top 1. Instead of traditional 2D drawings, we design on 3D models.
Eliminating Conflicts: Immediately detecting fire pipe collisions with air conditioning ducts or steel structural beams.
Accurate Hydraulic Calculation: BIM helps simulate flow and water pressure at the furthest nozzles, ensuring the PCCC pump is selected with the right capacity—no more, no less.
For server rooms, chemical warehouses, or CNC machinery areas in Amata, Chuan A always advises on gas suppression systems (FM-200, Novec 1230, CO2). The design must detail the Enclosure Integrity to ensure the suppression gas works most effectively without harming equipment.
Incorrect Sprinkler Head Placement: Due to not accounting for obstacles like cable trays or high-rack shelving.
Insufficient Smoke Extraction Capacity: Designs often ignore actual airflow calculations, leading to failed smoke tests.
Elevation Discrepancies: PCCC systems designed independently, not matching Architectural or MEP drawings.
Working with authorities in Dong Nai requires local procedural knowledge.
Dossier Preparation: Including design explanations, detailed technical drawings, and project approval certificates.
Submission: Chuan A directly works with the Dong Nai Fire Department or Amata IP Management to explain technical solutions.
Adjustment: Incorporating professional feedback and updating drawings to achieve the Design Approval Certificate in the shortest time.
At Chuan A, we don't sell drawings; we sell peace of mind.
Local Expertise: We understand the specific requirements of Amata IP and Dong Nai province.
Budget Optimization: Chuan A designs always aim for smart, durable materials with the most reasonable costs.
Full-service Support: From the first design stroke to the final inspection record.
Our mission is "Your Trust In Us" – Turning every blueprint into a true safety fortress for your business.
CHUAN A CONSTRUCTION INVESTMENT JOINT STOCK COMPANY